Description
HYDRAsub HSM500-ES Membrane can be run at very high flux (34 Lmh or 20 gfd average for 20 degrees Celsius urban applications), culminating in CAPEX savings and a smaller footprint. The assisted PVDF fiber and the ease of use dyrubg operation are two significant benefits which lead to an accurate and stable product.
Models
HYDRAsub® – MBR | HSM500-ES | |
Module |
Configuration: Fiber Orientation: Filtrate Flow: Membrane Polymer: Pore Size (nominal): Fiber Dimensions: Number of Elements in Module: Nominal Membrane Area per Module: Permeate Connections: Air Connections: Guide Pipe Connections: Typical Module Dry Weight: Typical Module Wet Weight: |
Submerged Membrane Vertical Bi-directional Polyvinylidene Flouride (PVDF) 0.4 μm OD 0.11″ (2.8mm) 20 (25 m² each) 5382 ft2 (500 m²) Two- 2” FNPT Connections Two- 2” FNPT Connections To fit 2” pipe 1166 lbs (530 kg) 2449 lbs (1111 kg) |
Operating |
Maximum Trans Membrane Pressure(Vacuum): Maximum Backwash Pressure: Maximum Instantaneous Chlorine Concentration: Maximum Chlorine Tolerance: MLSS Range: Operating Temperature Range: Feed Water pH Range: Cleaning pH Range: Operating Mode Aerator Pressure Loss @ Maximum Air Flow (excluding hydraulic head): |
-6 psig (-0.41 bar) 2 psig (0.14 bar) 5,000 ppma 742,000 ppm-hrsb 8,000-12,000 mg/Lc 41-104°F (5 -40°C) 6.0-8.0 1.0 – 11.0 Outside to Inside 0.58 psig (0.04 bar) |
Typical |
Operating Filtrate Flux†: Peak Operating Flux†: Nominal Air Flow: Air Flow Range: Chemically Enhanced Backwash (CEB) Flux: CEB Chemicals: Clean In Place (CIP) Flux: CIP Chemicals: |
4-20 gfd (7-34 lmh) 30 gfd (51 lmh) 90 scfm (152 Nm³/hr) 69 -103 scfm (117-175 Nm³/hr ) 2.4 gfd (4 lmh) NaOCld 2.4 gfd (4 lmh) NaOCl or Citric Acidd |
Features
- Very high flux
- CAPEX savings
- Lower footprint
- PVDF fiber
- Reliable and robust product
Applications
- Effluent (sewage or industrial source)
- Municipal applications