Description
HYDRAsub MAX HSMM1200-ES Membrane is designed with hollow fiber PVDF submersed modules to work specifically for MBR applications. MBR, and particularly HYDRAsub ®, produces high purity water that is ideal for reverse osmosis as opposed to conventional activated sludge treatment. Thus, significantly reducing footprint at higher MLSS.
Models
HYDRAsub®MAX- MBR | HSMM1200-ES | |
Module |
Configuration: Fiber Orientation: Filtrate Flow: Membrane Polymer: Pore Size (nominal): Number of Elements in Module: Nominal Membrane Area per Module: Permeate Connections: Air Connections: Guide Pipe Connections: Typical Module Dry Weight: Typical Module Wet Weight: |
Submerged Membrane Vertical Bi-directional Polyvinylidene Flouride (PVDF) 0.5 μm 30 (40 m² each) 12,912 ft2 (1200 m²) (2)- 3” MNPT (2)- 2” MNPT (2)- To fit 3” pipe 1762 lbs (801 kg) 3400 lbs (1543 kg) |
Typical Process Conditions |
Operating Filtrate Flux†: Peak Operating Flux†: Chemically Enhanced Backwash (CEB) Flux: CEB Chemicals: Clean In Place (CIP) Flux: CIP Chemicals: |
4-20 gfd (7-34 lmh) 30 gfd (51 lmh) 2.4 gfd (4 lmh) NaOCld 2.4 gfd (4 lmh) NaOCl or Citric Acidd |
Features
Features
- Maximum Trans Membrane Pressure (Vacuum): -6 psig (-0.41 bar)
- Maximum Backwash Trans Membrane Pressure: 2 psig (0.14 bar)
- Maximum Instantaneous Chlorine Concentration: 5,000 ppma
- Maximum Chlorine Tolerance: 742,000 ppm-hrsb
- MLSS Range: 8,000 – 12,000 mg/Lc
- Operating Temperature Range: 41 – 104°F (5 – 40° C)
- Feed Water pH Range: 6.0 – 8.0
- Cleaning pH Range: 1.0 – 11.0
- Operating Mode: Outside to Inside
Applications
- HYDRAsub MAX HSMM1200-ES Membrane is designed for municipal and industrial wastewater applications (chemical, textile, food and beverage or palm oil applications among many others).